Sign In | Join Free | My portofva.com |
|
Certification : ISO, CE
Supply Ability : 100/Year
Payment Terms : L/C, T/T, D/P
Brand Name : GENY
Model Number : YC1893D
Place of Origin : CHNA
Model NO. : YC1893D-12
Display : Digital
Installation : Direct Connected
Usage : Multi-Functional Energy Meter, Watt-Hour Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Prepayment Meter, Reactive Energy Meter, Multi-rate Watt-hour Meters, Maximum Demand Meter
Electric Equipment : Three-phase Three-wire
Theory : Electronic Meter
Power Meter Connection : Terminal
Measured Signal : Pulse Peak
Type : Energy Meter
Customized : Customized
Trademark : GENY
Transport Package : Plywood Case
Specification : 12.4CBM
Origin : China
HS Code : 9030849000
Port : Guangzhou, China
YC1893D Three Phase Meter Test System
Features& Functions
Application Conditions and Requirements | |||||
Environment | Power Requirement | Safety | |||
Operation | Humidity | Altitude | Voltage Supply | IP Class | Conformity |
Temperature | |||||
-10ºC--+40ºC | 0.5 | <2500m | 3x220/380V±10%(or customized) | IP30 | CE conform |
50/60Hz±2Hz | |||||
Type | YC1893D-6 | YC1893D-12 | YC1893D-24 | YC1893D-48 | |
Number of meter positions | 6 | 12 | 24 | 48 | |
Accuracy | 0.05 | ||||
Power Source | YCS-103-250 | YCS-103-600 | YCS-103-1200 | YCS-103-2500 | |
Reference Standard Meter | SZ-03A-K8 | ||||
Scanning Head | YCG-2-series | ||||
Voltage | |||||
Test voltage output(Phase-Neutral) | 3x(24V-300V)(or customized) | ||||
Power of the voltage output | Max.3x100VA | Max.3x250VA | Max.3x500VA | Max.3x1000VA | |
Resolution | Better than 0.01%of full scale value of range | ||||
Setting accuracy | Better than 0.05%at the final range value | ||||
Stability | Better than 0.005%/h(integration time 150 s) | ||||
Load regulation from 0-max.load | Better than 0.01% | ||||
Distortion factor | Better than 0.3% for linear resistance load | ||||
Harmonics | 2nd-41st free programmable | ||||
Current | |||||
Test current output | 3x(1mA-120A/200A) | ||||
Power of the current output | Max.3x250VA | Max.3x500VA | Max.3x1000VA | Max.3x2000VA | |
Resolution | Better than 0.01% of full scale value of range | ||||
Setting accuracy | Better than 0.05% at the final range value | ||||
Stability | Better than 0.005%/h(integration time 150 s) | ||||
Load regulation from 0-max.load | Better than 0.01% | ||||
Distortion factor | Better than 0.3% for linear resistance load | ||||
Harmonics | 2nd-41st free programmable | ||||
Phase angle | |||||
Range | 0-360° | ||||
Resolution | 0.01° | ||||
Setting accuracy | 0.1° | ||||
Frequency | |||||
Range | 45Hz-65Hz | ||||
Resolution | 0.01Hz | ||||
Error display | |||||
Type of error display | Red LED | ||||
Resolution of the error displays | 8 digits |
![]() |